供应


仪表网供应网 测量/计量 其它测量 其它测量Sensyflow FMT200-ECO2

Sensyflow FMT200-ECO2

  • 产地
  • 所在地
  • 暂无
  • 上海上海

更新时间:2025-05-18

有效日期:还剩92

产品详情

fjrigjwwe9r1dt_article:content

Sensyflow FMT200-ECO2 is a very compact and extremely dynamic mass flow meter for air. It offers a direct mass or standard volume flow measurement in pneumatic applications, e.g. in paint robot control. A multi-variable connection system makes the Sensyflow FMT200-ECO2 easy to install in many different tubes or pipes. Analog and digital output signals allow for flexible signal processing.

  • Compact design (IF Design award)
  • Variable process adapters: tubes, threads, ISO-KF flanges DN25
  • Variable, adjustable output signals
  • Measuring range 1..100 kg/h (=12....1250 l /min)
  • Serial port RS 232
fjrigjwwe9r1dt_article_attribute_value:technicalparameters
2 Specifications
Measuring principle Thermal: hot-film anemometer Input
Measured medium
Air
Measuring ranges1)
0 (1) ... 100 kg / h or 0 (12) ... 1250 Nl / min2)
Output
Analog output signal
0 ... 5 V
0 ... 10 V
0 / 4 ... 20 mA
Load
< 500 Ω
Error indication
< 3.5 mA or > 22 mA
Digital output
24 V, 20 mA
Frequency output
variable 1 ... 2500 Hz
Counter pulse
Pulse evaluation and pulse duration configurable
Alarm values
Minimum and maximum, adjustable
Polarity adjustable
Characteristics
Measured error
< ± 3 % of measured value
Repeatability
< ± 0.5 % of measured value
Response time
T63 » 25 ms; T98 » 90 ms Influences Temperature effect
< 0.1 % / K of measured value
Pressure effect
≤ 0.2 % / 100 kPa (/bar) of measured value
Pressure drop
< 10 kPa (100 mbar) at full scale and using the small flange adapter DN 25; decreasing quadratically for smaller flow rates.
Environmental conditions
Ambient temperature for flowmeter sensor
0 ... 50 °C (-13 ... 122 °F)
Degree of protection
IP 65
Storage temperature
-25 ... 85 °C (-13 ... 185 °F)
Measured medium conditions
Measured medium temperature
0 ... 50 °C (32 ... 122 °F)
Measured medium pressure
Standard: 10 x 102 kPa (10 bar abs.) High pressure version: 16 x 102 kPa (16 bar abs.)
Construction
Weight
0.51 kg (accessories see ordering information)
Material
Flowmeter sensor: aluminium, Hostadur, tinned Cu, glass Process connections: aluminium
Fittings: aluminium
Process connection
Small flange adapter ISO KF flange; Threads G 3/8“, G 3/4“, G 1/2“, G 1“; Legris tube adapter, Transair adapter
Electrical connection
Sub-D connector, serie 712, 8-pin, IP 65
Power supply3)
Voltage
24 V DC ± 10 %
Power consumption
< 15 W
Current consumption
Peak < 1 A; operation < 0.6 A
Slow-blow fuse of at least 2 A recommended
Communication interface
RS 232
Approvals for explosion protection (zone 2 and zone 22)
Gas: ATEX II 3 G EEx n A II T4 X Dust: ATEX II 3 D T 135 °C IP 65 X
Accessories (optional)
- Inlet and outlet runs
- Pipe fittings
- Connection adapter
- Quick-clamping connectors
- Reducers
- Power supply unit
- Display unit
- Display and supply unit completely installed in an IP 65 housing
1) Approximate values are given for applications with air under atmoshperic conditions. The values in brackets indicate the low limit of the measuring range for which the measured value accuracy indicated is specified.
2) It is possible to specify any unit which you can transform into a mass or standard volume flow. (Can also be written as: l / min-qn).
3) Power supply with safe electrical separation in accordance with EN 61010 and IEC 950, with max. output power of 150 W.

免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,仪表网对此不承担任何保证责任。

在线询价

上海萨海测量技术有限公司

联系我时,请说明是在仪表网上看到的,谢谢

商家概况

主营产品:
公司性质:
其他

该商家其它产品

湿度发生器SY-HG109

湿度发生器SY-HG1...

摘要:SEASYSY-HG109湿度发生器采 [详细]
HMM210系列湿度模块

HMM210系列湿度模...

摘要:fjrigjwwe9r1dt_article:co [详细]
温湿度探头 HMP155

温湿度探头 HMP15...

摘要:温湿度探头HMP155 [详细]
温湿度探头 HMP110

温湿度探头 HMP11...

摘要:fjrigjwwe9r1dt_article:co [详细]
温湿度变送器探头 HMP60

温湿度变送器探头...

摘要:fjrigjwwe9r1dt_article:co [详细]

其它商家同类产品


高级服务



媒体平台

更多>

新浪微博行业头条商务合作媒体合作建议反馈


新手指南
了解仪表网卖家注册买家注册操作指南手机版仪表网
旗下子站
流量仪表温度仪表压力仪表液位仪表气体检测工控仪表
站点导航
找资讯找企业找产品找展会找品牌
本站服务
会员服务企业建站广告服务SEO优化兴旺通在线投诉