Alba-STED FLIM/FFS 激光扫描荧光寿命成像系统

  • 产地
  • 所在地
  • 暂无
  • 暂无

更新时间:2024-11-13

有效日期:还剩91

产品详情

Over View

The instrument for quantitative cell biology at single-molecule detection.

Stimulated Emission Depletion (STED) is a powerful microscopy technique that allows for the observation of fluorescence structure with spatial resolution below the diffraction limit. The Alba-STED uses the pulsed excitation and pulsed depletion approach (pSTED) in combination with the digital frequency domain fluorescence lifetime imaging (FastFLIM) to record the time-resolved photons which allows for an increase in the image resolution and the separation of two labels with the same excitation wavelength.

Key Features of Alba-STED for FLIM/FFS:

  • pSTED (Pulsed excitation and pulsed STED)
  • FastFLIM for time-resolved pSTED acquisition
  • Improved image resolution using the phasor plot

  • Dual-label excitation
  • Fast image acquisition (dwell time: 0.2 µs)
  • High dynamic range (signal up to 60 million counts/s)

Measurements with Alba-STED for FLIM/FFS:

  • 1p or 2p confocal images
  • FLIM Fluorescence Lifetime Imaging (FastFLIM)
  • PLIM, Phosphorescence Lifetime Imaging
  • Polarization images
  • Fluorescence Fluctuations Spectroscopy (FCS, FCCS, PCS, FLCS)
  • RICS, N&B, Scanning FCS
  • Burst Analysis
  • FRET efficiency determination

Specifications for Alba-STED for FLIM/FFS

Instrument Features
  • Individual pinholes on each acquisition channel
  • Computer-controlled selection of the pinhole variable aperture
  • Computer-controlled positioning of the pinhole in the imaging plane
  • Single-photon or multi-photon excitation
  • Up to four channel data acquisition
  • Auxiliary port for camera
Acquisition and Analysis Software
  • VistaVision by ISS
STED laserPulsed, 775 nmAverage output power: 1 W
Pulsewidth: about 600 ps
Repetition rate: 0-100 MHz; or Ext. CLK
Beam quality: M2 < 1.1, TEM00
Amplitude noise: < 4.0% rms
Excitation laserPulsed, 640 nmPulsewidth (at medium power): 40-90 ps
Repetition rate: 20, 50, 80 MHz; or Ext. CLK
Power (at 50 MHz): up to 5 mW
Laser Launcher
  • Models for 3-, 4-, 6-laser. Light is delivered to the microscope through a single-mode fiber optic.
FastFLIM
  • 4 separate input signal
  • Dynamic range: up to 15 million counts/s per channel
  • Lifetime range: from picosecond to second
Microscope
  • Inverted or Upright
Objectives
  • Air objectives with 20X, 40X, 60X magnification and 1.5-8.1 working distances
  • Oil immersion objectives, 1.4 NA and 60X (standard); other aperture available
  • Water immersion objectives,1.2 NA 60X (standard), with coverslip correction (for 0.15-0.18 coverslip); other apertures available
Stages
  • Large distance movement (100x100x10 mm)
  • Stepper motor-controlled XYZ stage
  • Micro-distance movements
  • XYZ piezo-controlled stage, 100x100x50 µm with 5 nm step resolution.
Sample Holders
  • Microwell plates
  • Petri dishes
  • Coverslip
Light Detectors
  • GaAs PMT (Hamamatsu H7422P models)
  • Hybrid PMTs (Hamamatsu R10467U models)
  • SPADs
Image acquisitionFLIM acquisition: 0.2 µs dwell time
OS Requirements
  • Windows 10, 64-bit
Power Requirements
  • Universal power input: 110-240 V, 50/60 Hz, 400 VAC
Dimensions
  • 885 mm (L) x 600 mm (W) x 330 mm (H)
Weight
  • 40 kg

Measurements for Alba-STED for FLIM/FFS

FFS Measurements
  • Fluorescence Correlation Spectroscopy (single- and cross-correlation)
  • Photon Counting Histogram (PCH)
  • FFS measurements at target XYZ locations in an image
  • FLCS, Fluorescence Lifetime Correlation Spectroscopy
  • Scanning FCS
  • Number & Brightness (N&B)
  • Raster Image Correlation Spectroscopy (RICS)
Single-point Module Measurements
  • Intensity
  • Polarization
  • Kinetics
  • Lifetime
Imaging Module Measurements (Single plan and z-stack)
  • Intensity
  • Polarization
  • Ratiometric
  • FLIM
FLIM images (digital frequency-domain) (single plane and z-stack)
  • Acquired in digital frequency-domain (DFD). The routine acquires simultaneously a FLIM image and a steady-state image.
FLIM images time-domain (single plane and z-stack)
  • Acquired in time-correlated single photon counting (TCSPC)
Superresolution
  • STED
Single Molecule Module
  • Burst Analysis
  • FRET and Correlation Methods
  • PIE-FRET Methods

Schematic Diagram of Alba-STED for FLIM/FFS

Measurement Examples from Alba-STED for FLIM/FFS

Confocal (left) vs. pSTED (right) images of the actin labeled with the SiR dye in fixed glia cells, acquired by FastFLIM.

Confocal (left) vs. pSTED (right) images of the actin labeled with the SiR dye in fixed glia cells, acquired by FastFLIM.

Confocal images of 60nm fluorescence beads (left); pSTED images (middle); sharpening the pSTED image using a binary filter based on the phasor plots (right).

Dual labels can be separated using pSTED and FastFLIM. Atto 647N and Atto 655 were used as labels; they both are excited by the 640 nm laser. The two dyes are first separated using the phasor plots, and then assigned with two different false colors (Atto 647N - yellow, Atto 655 - purple) to produce the processed and merged pSTED image of the two labels.

Options and Accessories available for Alba-STED for FLIM/FFS

Non Descanned Detection (NDD) Port

enlarge
Detection through the Non Descanned Detection Port (NDD) is used in conjunction with multiphoton excitation; the fluorescence photons generated in the excitation spot of the laser are scattered back and collected right after the objective (without passing through the optics in the scanning path).

The Figure displays the NDD port on the Nikon Model Ti microscope coupled to the Alba. A raiser is introduced on the Nikon microscope above the epifluorescence port for connecting the NDD port and adding the filters-cartridge where the dichroic filters for the NDD detection are inserted. The detectors are mounted on an orthogonal mount complete of dichroic and filter holders. The NDD port uses either GaAs PMTs or hybrid detectors. The output of the detectors is diverted either to the data acquisition unit.
Laser Scanning Transmitted Detection Module with a Photon Counting PMT
enlarge
T-PMT is a transmitted detection module with a photon counting PMT that works with inverted microscopes.

The module is installed beside the microscope transmission illumination lamp and features a manual slider for selecting between the PMT and the lamp illumination.
Microscope Stages
enlarge

XYZ-stepper motor controlled stage for Microwell plates (8-, 96- and 384-wellplate)

The XYZ stage provides high resolution, highly repeatable, and fast controls for the X, Y, and Z position of the microscope stage; it utilizes crossed-roller slides, a high-precision lead screw, and zero-backlash miniature geared DC servomotors for smooth and accurate motion. Controlled through the USB port, it is the ideal stage when measuring samples in a microwell plate.

VistaVision includes protocols for the automatic measurement at single points (FFS, lifetime, polarization); the user can select the sequential measurements on all the wells; alternatively, a set of wells can be selected for the measurements.


免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,仪表网对此不承担任何保证责任。

在线询价

天津东方科捷科技有限公司

联系我时,请说明是在仪表网上看到的,谢谢

商家概况

主营产品:
分子荧光光谱,激光粒度仪,红外碳硫仪
公司性质:
其他

该商家其它产品

3D-tracking 单颗粒三维跟踪及纳米成像模块

3D-tracking 单颗...

摘要:3D-tracking单颗粒三维跟踪 [详细]
Alba-STED  FLIM/FFS 激光扫描荧光寿命成像系统

Alba-STED FLIM/...

摘要:Alba-STEDFLIM/FFS激光扫描 [详细]
超快成像拉曼光谱仪-XploRA PLUS XS

超快成像拉曼光谱...

摘要:超快成像拉曼光谱仪-XploRA [详细]
HORIBA 激光散射粒度分布分析仪

HORIBA 激光散射...

摘要:HORIBA激光散射粒度分布分 [详细]
HORIBA LA­960 激光粒度仪

HORIBA LA­960 激...

摘要:HORIBALA­960激光粒度仪 [详细]

其它商家同类产品


高级服务



媒体平台

更多>

新浪微博行业头条商务合作媒体合作建议反馈


新手指南
了解仪表网卖家注册买家注册操作指南手机版仪表网
旗下子站
流量仪表温度仪表压力仪表液位仪表气体检测工控仪表
站点导航
找资讯找企业找产品找展会找品牌
本站服务
会员服务企业建站广告服务SEO优化兴旺通在线投诉