产品详情
P-1A 系列技术参数表 | ||
型号 | 额定动 作温度 | 实测动 作温度 | 保持 温度 | 极限 温度 | 额定 电流 | 额定 电压 | 安规认证 | |||||
UL | CUL | VDE | MITI | PSE | CCC | |||||||
P1-1A | 102℃ | 98±2℃ | 76℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
0.5A | ● | ● | ||||||||||
P2-1A | 115℃ | 111±3℃ | 83℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
0.5A | ● | ● | ||||||||||
P3-1A | 125℃ | 122±2℃ | 97℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
0.5A | ● | ● | ||||||||||
P4-1A | 130℃ | 126±2℃ | 102℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
0.5A | ● | ● | ||||||||||
P5-1A | 135℃ | 131±3℃ | 105℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
0.5A | ● | ● | ||||||||||
P7-1A | 150℃ | 145±2℃ | 120℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | |
0.5A | ● | ● | ||||||||||
P9-1A | 138℃ | 135±2℃ | 108℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
0.5A | ● | ● | ||||||||||
P10-1A | 117℃ | 113±3℃ | 88℃ | 180℃ | 1A | 250V | ● | ● | ● | ● | ● | ● |
0.5A | ● | ● |
P-2A 系列技术参数表 | ||
型号 | 额定动 作温度 | 实测动 作温度 | 保持 温度 | 极限 温度 | 额定 电流 | 额定 电压 | 安规认证 [●已通过 ○申请中] | ||||||
UL | TUV | CUL | VDE | MITI | PSE | CCC | |||||||
P1 | 102℃ | 98±2℃ | 76℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ● |
P2 | 115℃ | 111±3℃ | 83℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ● |
P3 | 125℃ | 122±2℃ | 97℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ● |
P4 | 130℃ | 126±2℃ | 102℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | ● |
P5 | 135℃ | 131±3℃ | 105℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | |
P7 | 150℃ | 145±2℃ | 120℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ||
P9 | 138℃ | 135±2℃ | 108℃ | 180℃ | 2A | 250V | ● | ● | ● | ● | ● | ● | |
P10 | 117℃ | 113±3℃ | 88℃ | 180℃ | 2A | 250V | ● | ● |
P-3A 系列技术参数表 | ||
型号 | 额定动 作温度 | 实测动 作温度 | 保持 温度 | 极限 温度 | 额定 电流 | 额定 电压 | 安规认证 | |||||
UL | CUL | VDE | MITI | PSE | CCC | |||||||
P0-3A | 84℃ | 82±2℃ | 55℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | |
P1-3A | 102℃ | 98±2℃ | 63℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
P2-3A | 115℃ | 111±3℃ | 75℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
P3-3A | 125℃ | 122±2℃ | 85℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
P4-3A | 130℃ | 126±2℃ | 90℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
P5-3A | 135℃ | 131±3℃ | 90℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
P7-3A | 150℃ | 145±2℃ | 100℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | |
P9-3A | 138℃ | 135±2℃ | 95℃ | 180℃ | 3A | 250V | ● | ● | ● | ● | ● | ● |
P-5A 系列技术参数表 | ||
型号 | 额定动 作温度 | 实测动 作温度 | 保持 温度 | 极限 温度 | 额定 电流 | 额定 电压 | 安规认证 | |||||
UL | CUL | VDE | MITI | PSE | CCC | |||||||
P0-5A | 84℃ | 82±2℃ | 55℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | |
P1-5A | 102℃ | 98±2℃ | 63℃ | 180℃ | 5A | 250V | ○ | ○ | ● | ● | ● | ● |
P2-5A | 115℃ | 111±3℃ | 75℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | ● |
P3-5A | 125℃ | 122±2℃ | 85℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | ● |
P4-5A | 130℃ | 126±2℃ | 90℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | ● |
P5-5A | 135℃ | 131±3℃ | 90℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | ● |
P7-5A | 150℃ | 145±2℃ | 100℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | |
P9-5A | 138℃ | 135±2℃ | 95℃ | 180℃ | 5A | 250V | ● | ● | ● | ● | ● | ● |
产品放大图与尺寸 | ||
|
术 语 解 释 | ||
额定动作温度(TF): | 温度保险丝按标准规定方法测试,改变其导电状态的温度。按基于IEC691的安全标准 规定,温度保险丝必须在上述温度+0/-10℃范围内动作。(日本电气用品管理法规定公差范围为+/-7℃范围内动作)。 |
实测动作温度: | 温度保险丝在硅油池内以每分钟0.5-1℃速率升温,检测电流小于100mA条件下所测得的熔断温度。它是温度保险丝的实际动作温度。 |
保持温度(TH): | 温度保险丝在通过额定电流时,能保持168小时而不会改变其导电状态的温度。 |
极限温度(TM): | 温度保险丝能承受10分钟而不曾发生重新接通现象的温度。 |
额定电流(Ir): | 温度保险丝能承载的电流。 |
额定电压(Ur): | 温度保险丝工作电压。 |
覆冰监测设备 GNSS位移站 土壤墒情自动监测设备 防爆型气象观测站 道路交通气象系统 光伏电站气象仪 水库水位监测器 降雨量测量仪 手持气象仪器 自动雪厚监测站 地裂缝监测一体机 天气现象检测器 倾角加速度监测站 便携水深探测仪 微型水质自动监测站 高速公路自动气象站 九要素便携式气象站 综合电子气象仪 应急管理手持气象仪器 水深探测仪 便携式测深仪 便携式六要素自动气象站 便携式多要素气象站 便携式五要素气象站 移动应急自动气象站 观测自动应急气象站 管式土壤含水率监测站 地表裂缝监测站 GNSS地表自动位移监测站 翻斗式雨量监测站 公园生态环境监测系统 小型超声波气象站 便携式气象测定仪 农田病虫害监测系统 浮标水质监测设备 多参数水质在线监测仪 大坝安全监测站 鱼塘水质监测设备 河道水质监测设备 森林气象站 金属款气象传感器 过程校验仪 超声波雪深监测仪 一体化取水水质监测微系统 超声波一体式气象站 气象土壤墒情在线监测站 太阳能校园气象站 水温电导率ph在线分析仪 在线叶绿素分析仪 在线叶绿素水温分析仪