4-Beams for unrivalled Precision, Reliability and Repeatability

The FLUXUS G706 combines highest precision with the advantages of non-invasive ultrasonic gas flow measurement.

With its 4 beams, in reflect mode providing 8 paths through the gaseous medium, the meter averages the result of up to 4 planes. This arrangement averages out cross-flow profile disturbances and achieves the optimum non-invasive compensation. On longer straight runs, the 4-Beam meter achieves outstanding accuracy performance due to the individually averaged path effects and can thus be used for redundancy measurements of custody transfer meters or leak detection.

Temperature compensated transducers, unique digital signal processing with superior noise suppression combined with a highly rugged design care for an unrivalled degree of reliabilialy, durability and accuracy - ensuring perfect operation of the system under the harshest field conditions and makes it even suitable for installations buried in the ground (IP68 rated).

Custody Transfer Accuracy

The G706 is capable of accuracy in the Custody Transfer class. Clamp-on meters installed will contain some uncertainty due to pipe uncertainties and pipe geometry. These can be minimized with careful installation, precise pipe wall measurements and especially based on the effects of the multiple 4-channel measurement of the G706. While installed “out of box” custody transfer accuracy is not possible, in many pipeline services like check-metering, leak detection and others, it can be possible to calibrate the meter in-situ to achieve Custody class accuracy (proven by industry independent Calibration Facilities - test reports are available upon request).

优点

Easy installation without process outages

When creating a new flow measurement point, a significant part of the costs are incurred by the installation work (line shut-down, pipe cutting, pipe flushing, etc.). These costs are significantly reduced using the G706 clamp-on technology that requires zero impact on pipe integrity while commissioning.

  • Highly Economical: No heavy equipment necessary for installation, thus being the ideal solution for remote locations, or poorly accessible areas.
  • 99% plant availability: The non-invasive measurement technology does not require any process shut-downs - neither for installation nor for any potential maintenance efforts
  • Extremely low maintenance – virtually zero maintenance due to use of solid couplant pads instead of high maintenance gels
  • Safety: The G706 clamp-on meter does not add any leakage risk. It also does not require any flanges or gaskest

Laboratory Accuracy under Field Conditions

High accuracy and proven laboratory performance under reference conditions is one task. Accuracy under field conditions is quite another thing:
  • FLEXIM‘s transducers automatically compensate for ambient temperature changes – according to ANSI/ASME MFC-5.1-2011. This ensures no false measurement readings during temperature swings (day / night)
  • FLEXIM‘s transducers are carefully paired according to their individual properties. This process lays the foundation for superior accuracies over a wide temperature and application range. It also ensures a negligible zero offset and facilitates the measurement of very low flow rates. There is no need for zeroing, or programmed “automatic zero” workarounds.
  • FLEXIM‘s transducers are all individually factory calibrated, with storage of the calibration data on a “Sensprom”chip. The calibrated transmitter automatically reads the individual calibration data, avoiding potential errors and making transducer exchanges easy.
For FLEXIM, accuracy is a topic we take seriously. FLEXIM‘s specified installed-accuracy claims can seem conservative but we firmly believe that clients expect us to over-perform rather than disappoint. Ask us, if you want to learn more about the total measurement uncertainty for your specific application.

应用

  • 油和气体
    • 地下气体储存和加工处理
测量不确定度
(体积流量)
±1...3 % of reading ±0.005 m/s
重复性
0.15 % of reading ±0.005 m/s
流速范围
0.01...35 m/s, depending on pipe diameter
防区发射机
ATEX/IECEx Zone 2, FM Class I /Div 2
供电电源
100-230VAC, 24DC, 12DC
可用传感器
Shear wave/Lamb wave
对于防爆区
ATEX/IECEx Zone 1/Zone 2
FM Class I - Div2
适用于管道尺寸范围
7mm ... 1600mm
适用于温度范围
-40°C ... +240°C / WI: -200°C ... +600°C
输出
4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary
输入
Pt100/Pt1000
4-20mA active/passive
Binary input
数字通信
Modbus RTU
Foundation Fieldbus
输入
Up to 4 Inputs (Temperature Pt100/Pt1000), current, voltage, binary
输出
Up to 4 Outputs: (active/passive) current, voltage, frequency, binary

免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,仪表网对此不承担任何保证责任。

在线询价

广州钛尔锐科技有限公司

联系我时,请说明是在仪表网上看到的,谢谢

商家概况

主营产品:
总氮分析仪
公司性质:
其他

该商家其它产品

FLEXIM G722 ST-LT 蒸汽流量计

FLEXIM G722 ST-L...

摘要:FLEXIMG722ST-LT蒸汽流量计 [详细]
FLEXIM G532 ST-LT 蒸汽流量计

FLEXIM G532 ST-L...

摘要:FLEXIMG532ST-LT蒸汽流量计 [详细]
G831 ST-HT 危险区域的高温蒸汽流量计

G831 ST-HT 危险...

摘要:G831ST-HT危险区域的高温蒸 [详细]
FLEXIM G831 ST-LT 危险区域的蒸汽流量计

FLEXIM G831 ST-L...

摘要:FLUXUSG831ST-LT危险区域的 [详细]
FLEXIM H831 用于危险区域的外夹式流量计

FLEXIM H831 用于...

摘要:FLEXIMH831用于危险区域的 [详细]

其它商家同类产品


高级服务



媒体平台

更多>

新浪微博行业头条商务合作媒体合作建议反馈


新手指南
了解仪表网卖家注册买家注册操作指南手机版仪表网
旗下子站
流量仪表温度仪表压力仪表液位仪表气体检测工控仪表
站点导航
找资讯找企业找产品找展会找品牌
本站服务
会员服务企业建站广告服务SEO优化兴旺通在线投诉