产品详情
厂家: 美国安捷伦/惠普 (24.5kg)
主机 HP 83480A , 插件 HP 83485A |
插件 HP 83485A ( 12.4GHz 20GHz ) Each channel has two selectable bandwidth settings. In the lower bandwidth mode: of 12.4 GHz, oscilloscope noise performance is excellent, while the 20 GHz mode provides greater fidelity for high-speed signals. The optical channel: is calibrated at 1310nm and 1550nm. It also has a switchable filter to produce a calibrated SDH/SONET reference receiver. Options:
|
The Agilent 83480A Digital Communications Analyzer is a modular platform that accepts up to two plug-in modules. It provides fast, repeatable waveform performance analysis with automated pulse and eye-diagram statistical measurements. Optical or electrical conformance tests to both user-defined and industry standard eye-diagram masks or pulse templates are easily executed.
Digital Communication Analyzer with:
Optical channel plug-ins
Backward Compatibility
HP 83480A Digital Communications Analyzer
The HP 83480A represents a significant advancement in the instrumentation used to view waveforms in high-speed digital communications.Industry-standard tests including mask tests as well as eye-diagram analysis including extinction ratio are made using easy-to-use, built-in measurements.For measuring optical signals, lightwave receivers are integrated into the instruments to provide highest accuracy and waveform fidelity.
With up to 50 GHz of bandwidth, the HP 83480A can be used on lowrate tributary signals through 10 Gb/s optical waveforms.
Industry Standard Masks
Achieve high-throughput waveform testing with both optical and electrical masks and templates including SDH, SONET, Gigabit Ethernet,and Fibre Channel standards. For guardband testing, use mask margins.Custom/user-defined masks can also be generated. Masks are automatically aligned and scaled.
Integrated Optical Receivers
The HP 83480A is a modular platform with a family of optical receivers with very high-speed internal photodiodes (2.5 GHz, 20 GHz, or 30 GHz bandwidths). For filtered measurements, filters are switched in with a simple keystroke to produce a calibrated reference receiver, or switched out for full bandwidth waveform analysis.
The HP 83480A can accept one or two plug-in modules for up to four measurement channels. Modules have two electrical channels or one optical channel and one electrical channel. The following optical/electrical plug-ins have 9/125 μm single-mode optical interfaces for 1310 and 1550 nm applications. The HP 83481A has a 20 GHz electrical channel and a 2.5 GHz optical channel with 155 and 622 Mb/s switchable filters.The HP 83482A provides a 40 GHz electrical channel and a 30 GHz optical channel. The HP 83485A provides a 20 GHz electrical channel and a 20 GHz optical channel with a 622 or 2488 Mb/s switchable filter. The HP 83485B provides a 40 GHz electrical channel and a 10 Gb/s filtered channel.
Two optical/electrical plug-ins have 62.5/125 μm optical interfaces for both single-mode and multimode measurement applications. For 1310 and 1550 nm applications, the HP 83486A has a 2.5 GHz optical channel with 155 and 622 Mb/s switchable filters for SDH/SONET/ATM applications or 1063 and 1250 Mb/s switchable filters for Fibre Channel and Gigabit Ethernet. For 850 nm applications, the HP 83487A has a 2.5 GHz optical channel with 1063 and 1250 Mb/s switchable filters (Fibre Channel and Gigabet Ethernet). Both modules also have a 20 GHz electrical channel.
Accurate Eye-Diagram Analysis
Integrated optical receivers are the key to accurate eye-diagram analysis of lightwave signals. Internal photodiodes have well-behaved frequency responses which are not degraded by external cabling and adapters. This yields the highest in waveform fidelity and measurement accuracy. Extinction-ratio measurements are accurate and repeatable.
General-Purpose Oscilloscopes
In addition to digital communications analysis, the HP 83480A can be used as a general-purpose, high-speed, sampling oscilloscope. The HP 83483A electrical plug-in provides two 20 GHz electrical channels,the HP 83484A has two 50 GHz electrical channels. Add TDR capability to the HP 83480A with the HP 54755A software and TDR module HP 54753A or HP 54754A (see page 116). The HP 11898A module extender provides a 1.5 meter extension cable for placing the electrical module adjacent to the high-speed circuit-under-test.
模块主要指标:
兼容性
83481A 3 GHz光模块/20 GHz电模块
83482A 30 GHz光模块/40 GHz电模块
83483A 20 GHz 双通道电模块
83484A Dual Channel 50 GHz Electrical Plug-In Module
83484B Single-Channel 50 GHz Electrical Plug-In Module
83485B 30 GHz光模块/40 GHz电模块
83486A 3 GHz光模块/20 GHz电模块
83487A 3 GHz光模块/20 GHz电模块
热保护开关 蒸气老化试验机 数据通信用ASM系列矩形连接器 制砖机液压站 工程宝HVT-2000 应急行业便携式气象仪 可程式恒温恒湿试验仪 真空校验仪 管线式高剪切乳化泵 QJNZ钢筋扭转试验机 二通内螺纹旋塞阀 螺纹式隔膜电接点压力表 饮用冷水水表和热水水表第1部分:计量要求和技术要求 管段式超声波热量表 万向坡度测量仪 手持危险液体探测仪 烟气管道蝶阀 重庆奥特数码一体化生物显微镜SMARTE-320 高低湿热温试验箱 分光旋光仪 检测端隔离式安全栅 微水仪 浮动软密封球阀 微型计算机控制技术实用教程 YHB系列立式齿轮油泵 两点内径千分尺 现代传感器技术与应用 mmb手持式高精度信号发生器 机械钟 氧氮氢气体分析仪 机械搅拌式浮选机 液体流量计量控制仪 液相色谱检测方法 便携式多功能超声波相控阵成像检测系统 电子水表传感与信号处理技术 便携式折叠硅胶键盘超声波清洗机 电磁式高频振动试验机 防震压力表 手持式光万用表 计数秤 雨量传感器 应急便携式流速仪 便携式分光测色仪 阿里巴流量计 示差折光监测器 氙气老化机 数字互感器 防爆型热电偶 电子技能实训(双色) 视频测量仪