产品详情
国标YJV26/35KV高压交联电力电缆厂家
6kV~35kV 中低压铜芯及铝芯交联聚乙烯绝缘电力电缆(YJV电缆,YJV22电缆,YJLV电缆,YJLV22电缆) XLPE Insulated Power Cable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
交联聚乙烯绝缘电力电缆是采用化学方法或物理方法,使聚乙烯分子由线型分子结构转变为三维网状结构,由热塑性的聚乙烯变成热固性的交联聚乙烯,从而提高了聚乙烯的耐老化性能、机械性能和耐环境能力,并保持了优良的电气性能。 国标YJV26/35KV高压交联电力电缆厂家 交联聚乙烯绝缘电力电缆导体的允许长期Z高温为90摄氏度,较低绝缘电缆、聚氯乙烯绝缘电缆和聚乙烯绝缘电缆高,且具有重量轻、结构简单、使用方便、耐化学腐蚀和敷设不受落差限制等优点。 26/35KV电力电缆,18/30KV交联电缆,12/20KVYJV电缆,8.7/15KVYJV22电缆线,6/10KV铝芯交联电缆线,3.6/6KVYJLV单芯电缆 中低压交联电缆产品标准 Standard 本产品按GB12706《额定电压35V及以下铜芯、铝芯塑料绝缘电力电缆》标准生产,同时还可根据用户需要按电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。 The product is manufactured according to the standard of《GB12706 or IEC、BS、DIN and ICEA upon request. 适用范围 Applications 国标YJV26/35KV高压交联电力电缆厂家本产品适用于工频额定电压3.6/6kv~26/35kv输配电线路作配送电能子用。 The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv. 使用特性 Operating characteristics · 工频额定电压U0/U为3.6/6kv~26/35kv。 Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv. · 电缆导体的Z高允许工作温度:90℃。 Max.admissible operating temperature of the conductor:90℃. · 短路时(Z长时间不超过5s)电缆导体的Z高温度不超过2500C。 Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration) · 电缆敷设时环境温度应不低于00C。 The ambient temperature under installation should not below 00C. · 电缆弯曲半径:三芯电缆不小于电缆外径15倍;单芯电缆不小于电缆外径20倍。 The bending radius of a single-core cable should not less than 20 times of the cable diameter. The bending radius of a single-core cable should not less than 15 times of the cable diameter. 电缆额定电压的选择 Voltage designation · 电缆的额定电压应适合于电缆系统的运行状况,用U0/U(Um)kv表示。 U0-电缆设计用的导体对地或金属屏蔽之间的额定工频电压; U-电缆设计用的导体间的额定工频电压; Um-设备可承受的“Z高系统电压”的Z大值。 The rated voltage of the cable for a given applixation shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv Where: U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed; U - The rated power-frequency voltage between conductos, for which the cable designed; Um- The maximum value of the“highest system voltage”for which the equipment may beused. · 三相系统用电缆的U0值推荐如下表: The values of U0 recommened for cable to be used in three-phase systems are listed below: 国标YJV26/35KV高压交联电力电缆厂家 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
A类系统──该类系统任何一相导体与地和接地导体接触时,能在1min内与系统分离 B类系统──该类系统仅包括单相接地故障短时运行的条件,接地故障时间应不超过1h, 但在任何情况下,Z长不超过8h每年接地故障总持续时间不超过125h; C类系统──不属于A类、B类的系统。 System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min. System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h. System categeory C──This category comprises all systems which do not fall into A and B 电缆的型号Type of cable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
生产范围Production range of cable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
UR液位变送器 分散机原理 峰值电压表 螺杆泵选型 自动氧指数测定仪 佑富UT系列超声波物位计 浮球水位计 双头面筋测定仪 头盔式红外热像仪 高英杰 DMF-65电磁脉冲阀 超高低温记录仪 2X旋片式真空泵 YML隔膜压力表 五高熔断器 汽车后视系统 JJ-Y系列电子天平 导轨式电表 4803A加速度传感器 陀螺经纬仪定向精度及稳定性 BSN900HF 焊缝超声波探伤仪 气象水文卫星接收设备 本安电磁阀 复合膜拉力机 反相气相色谱法 成丰涡街流量计 涡流探伤机 液相制备色谱仪 测量测试仪器 活塞式压力真空计 双法兰立式振动电机 智能负氧离子监测站 六要素微型气象仪 6要素气象传感器 六要素气象监测仪 6要素微型气象仪 鼠类监测设备 鼠害监测仪 鼠害监测设备 鼠害监测系统 老鼠监测站 鼠情自动监测系统 鼠害智能监测设备 鼠害智能监测系统 鼠情智能循环诱控装置 草原鼠害监测系统 鼠情监测设备 鼠害监测站 智慧农业害虫性诱监测专用设备 稻飞虱在线测报仪