Dimensioning specifications for quenching diode:
Rated voltage at diode: UD ∫ 1,4 x Us
Rated current at diode: N ∫ ILast
Selection of a quick switching diode (recovery time trr √ 200 [ms]).
RC link in parallel to load in parallel to switching contact.
Suited for DC and AC voltage.
Dimensioning principles:
R in Δ ≈ 0,2 x RLoad in Δ
C in [μF] ≈ ILoad in [A]
Acuation: Solenoid pilot operated
Design: Piston seat valve
Fluid: Filtered air, lubricated or unlubricated 1)
Temperature range: -10 to +60°C
Mounting position: Valve spindles vertical
Monitoring: Internal, with dynamic
self-monitoring function
and pressure balance
Parameters and order numbers
P A R min. max. Body Seals P – A A – R [kg] Valve Solenoid
32 G 1 G 1 G 1 1/2 2 8 Al Au 500 800 165 7,5 XSz 32 5 2493131.0801
50 G 1 1/2 G 2 G 2 2 8 Al Au 1200 2000 165 15,5 XSz 50 6 2493231.0801
Spare valves:
V61B517A-A213J,英NORGREN呼吸空气过滤器
Spare valves may only be operated with the original HERION subplate (see page 16). The spare valve is equipped with a new seal. When changing the
valves, the sealing surfaces must be clean and the seals must be properly positioned. Prior to commissioning, a test must be carried out according to the
operating instructions and test instructions (see page 18).
1) Oil recommendation: Shell Hydrol DO 32, Esso Febis K 32 (as of 07/92) or similar oils with DVI values <8 (DIN 53521) and ISO viscosity class 32-46
(DIN 51519).
Filtration: 25 to 50 μm.
Note:
If two press safety valves are used on presses with separay arranged clutch and brake, the contacts of the two pressure
switches must be integrated into the press control in such a way that both valves are de-energized in case one of
them malfunctions.
For technical data on pressure balance, see page 15.